为提高解离增强镧系荧光免疫分析(DELFIA)的灵敏度或信/噪比,进行了一些重要的方法学研究.观察到了对于不同的铕量,荧光响应和信/噪比都随着增强液体积而明显地变化.对于确定的铕量,存在一个最佳体积,且铕量越小,其最佳体积也越小.实验中选择最佳体积是重要的.研究了增强液制备技术,发展了微滴定板条有效的清洗和干燥方法,使本底荧光明显降低.
Factors influencing the sensitivity, or the signal/noise ratio.of dissociation enhanced lanthaqide fluoroimmunoassay (DELFIA) have been studied. The fluorescence responses and signal/noise ratios for different europium amount were shown to be changed with the volume of enhancement solution.and there was an optimum volume at a certain europium amount.The smallest europium amount leads to the smallest optimum volume.20/00 of the net fluorescence intensity was increased by using tinfoil reflection layer. Effective washing and drying methods of microtitration strips decreased background fluorescence have been developed.
赵启仁,张福华,刘洁,林汉.解离增强镧系元素荧光免疫分析灵敏度的改进[J].生物化学与生物物理进展,1994,21(3):255-258