将脂肪酶固定在pH玻璃电极上,制成甘油三酯酶传感器.对传感器的制作方法和响应性能进行了研究.在37℃,选择Tris-HCl缓冲溶液(pH 8.5)为测量介质, 所制传感器对甘油三酯的响应线性范围为3.09×10-6~1.91×10-3 mol/L,响应斜率为32.7 mV/pC, 响应时间为5~10 min, 使用寿命可达25 d.用研制的传感器测定了人和兔血清中的甘油三酯含量,结果满意.
A triglyceride enzyme sensor has been prepared by immobilizing lipase on pH glass electrode. The immobilized methods of lipase and the response characteristics of the sensor were studied.The linear range of detection is 3.09×10-6~1.91×10-3 mol/L for triglyceride with a slope of 32.7 mV/pC in the pH 8.5 Tris-HCl buffer solution at 37℃. The response time is 5~10 min. The sensor is relatively stable for 25 days.The sensor has been applied to the determination of triglyceride in serum with satisfactory results.
王永生,李贵荣,吕昌银,万载阳,刘传湘.甘油三酯酶传感器的研制及应用[J].生物化学与生物物理进展,1999,26(2):144-146
复制生物化学与生物物理进展 ® 2025 版权所有 ICP:京ICP备05023138号-1 京公网安备 11010502031771号