    摘要:

    应用电化学分析法对固定化酶丝素膜的性质进行了分析,结果表明这种酶经丝素膜固定后,活性得率高、性能稳定、能长期存放.用这种酶膜和氧电极等组成的流动注射分析式尿酸传感器对生物样品进行的百次重复分析结果表明,这种传感器的重现性良好,每小时能分析60个人血清样品.

    Abstract:

    Uricase-immobilized silk fibroin membrane was characterized by means of electrochemistry method. When uricase was immobilized in silk fibroin membrane, the immobilized uricase was improved largely at its stability to heat and pH, and it can be stored for long time. Based on this uricase membrane and oxygen electrode, an amperometric sensor has been developed for measurement of uric acid in flow injection analysis. The biosensor has a good reproducibility for repeatedly monitoring biosamples for 100 times respectively and is capable of detecting over 60 serum samples per hour.