    摘要:

    目的 光声泵浦成像可以有效排除传统光声成像中血液背景信号的干扰,实现深层组织内微弱的磷光分子及其三重态寿命的成像。然而,光声泵浦成像中背景差分噪声常常导致磷光分子浓度和三重态寿命的拟合结果偏大。为此,本文提出了一种新型的应用于光声泵浦成像中的三重态寿命拟合方法,通过提取三重态差分信号和背景噪声的相位,有效矫正背景噪声造成的拟合偏差。方法 通过数值仿真、仿体和活体实验,分别验证了新提出算法的优势和可行性。结果 数值仿真中,在噪声强度为信号幅值10%的条件下,新方法可将拟合偏差从48.5%优化到5%左右,并有更高的可决系数(0.88>0.79),极大地提高了拟合精度。仿体实验证明了光声泵浦成像对磷光分子高特异性成像的能力。活体实验验证了本文提出的新拟合方法在裸鼠肿瘤的光动力治疗中拟合磷光寿命以监测氧分压含量的可行性。结论 本工作对于光声泵浦成像在生物医学中的应用将起到重要的推进作用。

    Abstract:

    Objective Photoacoustic pump-probe imaging can effectively eliminate the interference of blood background signal in traditional photoacoustic imaging, and realize the imaging of weak phosphorescence molecules and their triplet lifetimes in deep tissues. However, background differential noise in photoacoustic pump-probe imaging often leads to large fitting results of phosphorescent molecule concentration and triplet lifetime. Therefore, this paper proposes a novel triplet lifetime fitting method for photoacoustic pump-probe imaging. By extracting the phase of the triplet differential signal and the background noise, the fitting bias caused by the background noise can be effectively corrected.Methods The advantages and feasibility of the proposed algorithm are verified by numerical simulation, phantom and in vivo experiments, respectively.Results In the numerical simulation, under the condition of noise intensity being 10% of the signal amplitude, the new method can optimize the fitting deviation from 48.5% to about 5%, and has a higher exclusion coefficient (0.88>0.79), which greatly improves the fitting accuracy. The high specificity imaging ability of photoacoustic pump imaging for phosphorescent molecules has been demonstrated by phantom experiments. In vivo experiments have verified the feasibility of the new fitting method proposed in this paper for fitting phosphoometric lifetime to monitor oxygen partial pressure content during photodynamic therapy of tumors in nude mice.Conclusion This work will play an important role in promoting the application of photoacoustic pump-probe imaging in biomedicine.