College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology,College of Bioengineering,Tianjin University of Science Technology,Tianjin Key Laboratory of Industrial Microbiology,Ministry of Education Key Laboratory of Industrial Microbiology

Clc Number:

Fund Project:

This work was supported by grants from the Ministry of Science and Technology of China (2013DFG52490), Tianjin Municipal Science and Technology Commission (12ZXCXSY07500), The National Natural Science Fundation of China (21076157)

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    A new aptamer biosensor for detection of cTn I was established. It can detect cTn I in samples. The surface of GC was modified with anode-oxidation, amidation and activation modification. We used EDC and NHS as activators. Due to aptamer's specificity for cTn I, we can detect the concentration of cTn I in sample solution. The linear range of the analytical signal is observed from 0.05~5 nmol/L. The lowest detected concentration is 0.05 nmol/L. The detection time is 5 min.

    Reference
    Related
    Cited by
Get Citation

JIANG Shu-Hai, FAN Ting, LIU Li-Juan, CHEN Yi, ZHANG Xiao-Qing, SHA Zuo-Liang, LIU Yu-Liang, ZHANG Juan-Kun. The Detection of cTnⅠ by The Aptamer Biosensor[J]. Progress in Biochemistry and Biophysics,2014,41(9):916-920

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:September 30,2013
  • Revised:December 23,2013
  • Accepted:December 30,2013
  • Online: September 22,2014
  • Published: September 20,2014