A Fitting Method for Photoacoustic Pump-probe Imaging Based on Phase Correction
Author:
Affiliation:

1)Department of Biomedical Engineering, School of Basic Medical Science, Central South University, Changsha 410083, China;2)State Key Laboratory of Low-Dimensional Quantum Physics, Department of Physics, Tsinghua University, Beijing 100084, China

Clc Number:

Fund Project:

This work was supported by grants from the Natural Science Foundation of Hunan Province (S2023JMSXM2215, 2022J30756).

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective Photoacoustic pump-probe imaging can effectively eliminate the interference of blood background signal in traditional photoacoustic imaging, and realize the imaging of weak phosphorescence molecules and their triplet lifetimes in deep tissues. However, background differential noise in photoacoustic pump-probe imaging often leads to large fitting results of phosphorescent molecule concentration and triplet lifetime. Therefore, this paper proposes a novel triplet lifetime fitting method for photoacoustic pump-probe imaging. By extracting the phase of the triplet differential signal and the background noise, the fitting bias caused by the background noise can be effectively corrected.Methods The advantages and feasibility of the proposed algorithm are verified by numerical simulation, phantom and in vivo experiments, respectively.Results In the numerical simulation, under the condition of noise intensity being 10% of the signal amplitude, the new method can optimize the fitting deviation from 48.5% to about 5%, and has a higher exclusion coefficient (0.88>0.79), which greatly improves the fitting accuracy. The high specificity imaging ability of photoacoustic pump imaging for phosphorescent molecules has been demonstrated by phantom experiments. In vivo experiments have verified the feasibility of the new fitting method proposed in this paper for fitting phosphoometric lifetime to monitor oxygen partial pressure content during photodynamic therapy of tumors in nude mice.Conclusion This work will play an important role in promoting the application of photoacoustic pump-probe imaging in biomedicine.

    Reference
    Related
    Cited by
Get Citation

XIE Zhuo-Jun, ZHONG Hong-Wen, LIU Run-Xiang, WANG Bo, XUE Ping, HE Bin. A Fitting Method for Photoacoustic Pump-probe Imaging Based on Phase Correction[J]. Progress in Biochemistry and Biophysics,2025,52(2):525-532

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:August 24,2024
  • Revised:January 10,2025
  • Accepted:October 01,2024
  • Online: October 05,2024
  • Published: February 28,2025